Company Logo

Online Visitors

CMZ 900

We Repair CMZ 900 Gyro Compass.
The official site of Yokogawa: http://www.yokogawa.com/

 

CMZ900B This type is suitable for small vessels. CMZ900B Gyrocompass Features The system configuration can easily be adapted to each vessel's specifications. IEC 61162-2 high-speed code is available for the heading and rate of turn (ROT) outputs. A unique anti-vibration system enhanced by the velocity damping effect of high viscous oil, provides superior damping of vibration and decoupling of shock at sea. A small and lightweight container enhances the follow up speed. The gyrocompass changes smoothly and does not lag when a small vessel rapidly changes course. A space-saving design: the master compass can be installed on the autopilot stand. The restart time can be preset from 1 to 99 hours. Top of this page Specifications Settling Time and Accuracy Settling time Within 5 hours (Operational state is reached in about 2 hours) Accuracy Static: ±0.25 deg.x sec (Latitude) Dynamic: ±0.75 deg.x sec (Latitude) Follow up accuracy 0.1 deg. or less Max. follow up speed 30 deg./s Environmental (Normal use) Permissible angle ±40 deg.(Roll), ±40 deg. (Pitch) Ambient temperature -10 deg.C to +55 deg.C Power Supply Main 24V DC AC adapter (Option), type MKR027 is available on 100V/110V/115V/220V AC 50/60Hz single-phase Alarm 24 V DC Signal Inputs External heading IEC61162-1 (NMEA0183) 1 circuit Options (Available on adding C.Operation unit, type MKR024) Automatic speed error correction Optional Latitude IEC61162-1 (NMEA0183) 1 circuit Ship's speed 200 P/nm or IEC61162-1 (NMEA0183) 1 circuit External heading (For deviation alarm) IEC61162-1 (NMEA0183) (Supplied to C.Operation unit, MKR024) 1 circuit Signal Outputs Heading data for repeater compasses 3 circuits Heading data for steppers 1 circuit Serial data IEC61162-1 1 circuit IEC61162-1/-2 selective 2 circuits Gyro. running (Close contact when running) 1 circuit Alarms (Open contact when abnormal) System failure 1 circuit No voltage 1 circuit

 

 

Warning**
All trademarks , products and logos mentioned in the text in this website belong to their corresponding owners.

 

 

Specifications

Settling Time
and Accuracy
Settling time Within 5 hours 
(Operational state is reached in about 2 hours)
Accuracy Static: ±0.25 deg.x sec (Latitude)
Dynamic: ±0.75 deg.x sec (Latitude)
Follow up accuracy 0.1 deg. or less
Max. follow up speed 30 deg./s

Environmental
(Normal use)

Permissible angle ±40 deg.(Roll), ±40 deg. (Pitch)
Ambient temperature -10 deg.C to +55 deg.C
Power Supply Main 24V DC
AC adapter (Option), type MKR027 is available on
100V/110V/115V/220V AC 50/60Hz single-phase
Alarm 24 V DC
Signal Inputs External heading IEC61162-1 (NMEA0183) 1 circuit
Options (Available on adding C.Operation unit, type MKR024)
Automatic 
speed error correction
Optional
Latitude IEC61162-1 (NMEA0183) 1 circuit
Ship's speed 200 P/nm or IEC61162-1 (NMEA0183) 1 circuit
External heading
(For deviation alarm)
IEC61162-1 (NMEA0183)
(Supplied to C.Operation unit, MKR024)
1 circuit
Signal Outputs Heading data for repeater compasses 3 circuits
Heading data for steppers 1 circuit
Serial data IEC61162-1 1 circuit
IEC61162-1/-2 selective 2 circuits
Gyro. running (Close contact when running) 1 circuit
Alarms (Open contact 
when abnormal)
System failure 1 circuit
No voltage 1 circuit


  • ANSCHUTZ GYROCOMPASS
  • Anschutz STD-4,
  • Anschutz STD-6, STD-12, STD-14
  • Anschut Gyrostar
  • Anchutz STD-20, STD22
  • SPERRY MARINE / C-PLATH
  • Navigat I, Navigat II - III
  • Navigat X MK1
  • Navigat X MK2
  • Nacigat 2100
  • TOKIMEC-Tokyo Keiki
  • ES-100 / GM-20 / GM-21
  • TG-5000
  • TG-6000
  • TG-8000
  • YOKOGAWA
  • CMZ 200
  • CMZ 300 / CMZ 300X
  • CMZ 500 / CMZ 700
  • CMZ 900
  • SIMRAD/ROBERTSON
  • RGC 11
  • RGC 12
  • RGC 50
  • GC 80/85

MarineHellas.com. Valid XHTML and CSS.